Key takeaways

  • Start with observation and the homeowner’s description, then use the meter to confirm what the senses and sequence suggest.
  • When a furnace stops, identify the exact point where its expected sequence of operation stops; that step narrows the diagnosis.
  • Run a repaired furnace through two or three complete cycles so the technician learns normal operation and catches remaining faults.
  • Use voltage for energized loads, continuity for de-energized circuits and safeties, and amperage to uncover motors that are overloaded despite appearing to run.
  • Do not assume thermostat wire colors remain consistent end to end; verify continuity and maintain consistent common-wire practices.
  • A furnace flame-sensing circuit needs a clean flame rod and a reliable ground; clean buildup without sandpaper and investigate grounding changes after electrical work.

Summary

Jim Foltz’s goal: make a furnace call a walk in the park

Host Brian Orr introduces Jim Foltz’s Troubleshooting 101 class from the 2026 HVACR Training Symposium, aimed especially at newer technicians entering heating season. Foltz, now with White-Rodgers after 36 years in the industry—including 15 years running a California company—says the class is elementary but focuses on the thought process behind diagnosis. He recalls taking an RSCS refrigerant-usage class in 1992, before EPA refrigerant restrictions existed, as a reminder that the trade keeps changing. His goal is to turn an intimidating furnace into a finite system of components and steps.

Observe the furnace before reaching for the meter

Foltz’s first rule is to develop a repeatable starting process: observe before measuring. He says technicians should look, listen, and smell, and should recreate the homeowner’s complaint exactly. A furnace control-board light often proves that 120 volts—and probably 24 volts through the transformer—are present. In Florida, a blank thermostat during cooling season first suggests dead thermostat batteries, though a condensate float switch may also have opened the thermostat circuit. The meter remains necessary to confirm conclusions, but using it without knowing where to place the leads turns diagnosis into guessing.

The sequence tells you where the failure is

Foltz says technicians must know the equipment’s sequence of operation and identify the exact step where it stops. For a typical 80% gas furnace, the board verifies its circuits and that the pressure switch is open, the inducer starts, the pressure switch closes, and the igniter warms for about 17 seconds at 120 volts. The gas valve then opens, flame must be proven within roughly five seconds, and the blower starts after its programmed delay. After the call ends, the gas valve closes, post-purge occurs, and the blower runs through its off-delay; a typical pre-purge is 15 seconds.

Learn normal by cycling the repaired furnace

Foltz warns that trade-school troubleshooting can create callbacks if a technician fixes the immediate fault, reassembles the furnace, and leaves without testing the complete cycle. He recommends running the furnace two or three times after repair to learn the normal sequence and catch delayed ignition or another remaining problem. He compares this to a bank teller learning genuine currency—watermarks, security strips, and paper threads—so counterfeit money stands out. Technicians should also ask whether the homeowner likes the blower off-delay: a longer delay extracts more heat, but some customers dislike the cool air at shutdown.

Trace one circuit instead of confronting “circuit spaghetti”

Foltz divides the furnace into high- and low-voltage areas and emphasizes that the parts list is limited: inducer, igniter, transformer, blower, gas valve, pressure and limit circuits, thermostat, and flame-sensing components. On a schematic, he advises tracing one circuit from point A to point B rather than trying to follow every wire at once. Components are generally connected in pairs—power and neutral, transformer leads, motor leads, or the two ends of a safety circuit—which makes replacing an integrated furnace control easier if wires are removed and grouped in pairs.

Choose voltage, continuity, or amperage for the actual question

Voltage testing is appropriate when a circuit is energized and the technician needs to know whether power reaches a load; continuity is useful when power is off or a safety circuit or fuse is open; amperage reveals whether a motor is working under abnormal load. Foltz recalls a technician using a box of five-amp fuses on a rooftop unit until Foltz found a rubbed limit-circuit wire by simply moving the wires and spotting an arc mark. For blown low-voltage fuses, he first suspects a recently installed thermostat or pinched thermostat wires, then rubbed condenser wires near pressure switches or copper tubing.

Motors and igniters require more than a basic pass/fail test

A 120-volt igniter should glow after the inducer runs; if it has voltage but no glow, it is failed, and a visible crack means replacement is imminent. Foltz contrasts porous, hand-sensitive silicon carbide with denser, tougher silicon nitride, which is still brittle enough to inspect before leaving the supply house. For PSC blowers, technicians should check voltage, free movement, bearing play, capacitor microfarads, and amp draw after replacing a capacitor; a tight motor may have caused the capacitor failure. Constant-torque ECM/X13 motors increasingly use DC control signals—often 8–18 volts—so technicians should measure DC as well as AC.

Flame rectification depends on a clean rod and a real ground

Foltz explains flame sensing as 120-volt current traveling through the flame’s positive ions to the grounded burner, with the circuit board detecting the rectified signal as roughly two to five microamps. A good furnace ground is essential; he describes a furnace that stopped working after an electrical-panel upgrade removed the prior grounding path. Flame rods should be cleaned gently with paper, an alcohol swab, steel wool, or aluminum-oxide cloth—not sandpaper, because silica insulates. Propane, laundry-room combustion air, detergents, and other VOCs can accelerate insulating buildup on the rod.

Gas valves, pressure switches, and truck stock finish the class

Modern furnace gas valves use DC coils behind an AC-to-DC rectifier, so Foltz says not to diagnose them by ohming the terminals: confirm inlet gas, verify 24 volts at the valve, and replace it if gas is present but does not pass. He once spent an hour diagnosing a propane furnace before discovering the tank was empty. Pressure-switch continuity should be checked from the wiring rather than by pulling and jiggling the switch, and inducer ports or internal squirrel cages may be obstructed. Foltz closes by promoting White-Rodgers cross-reference tools, universal controls, and stocking parts to avoid losing $200–$500 on a parts run.

Sponsors

  • Refrigeration Technologies · The episode promotes the Viper Wet Rag Heat Shield, a flame-resistant welding pad usable wet or dry, and the original reusable Wet Rag heat-blocking putty. The products protect valves, reversing valves, TXVs, electronic expansion valves, dryers, compressors, and air-handler surfaces during brazing. The read mentions offer code GETSCHOOLED for a discount through TruTech Tools.
  • Carrier · Brian Orr says he has been a Carrier dealer for many years and highlights Carrier’s GreenSpeed Extreme high-efficiency heat pumps.
  • Copeland and White-Rodgers · The White-Rodgers Hot Rod Combo, part number 21D64C-843, combines a universal 120-volt silicon nitride hot-surface igniter and universal flame sensor. Each replaces more than 150 OEM parts; the igniter is stronger and more corrosion-resistant than silicon carbide, while the flame sensor can be cut and bent for a custom fit.
  • Santa Fe Dehumidifiers · Santa Fe promotes its Peace of Mind warranty program, offering five-year complete replacement coverage plus an additional year for parts. Brian says the reliability support gives his company, Kalos, confidence in offering the product line.
  • TruTech Tools · TruTech Tools is described as an expert-supported catalog with more than 90 brands, field-experienced technical support, free worksheets and resources, shipping to all 50 states and U.S. territories, and continued support for HVAC training. The read again mentions offer code GETSCHOOLED.

Show notes

In this session from the 2026 HVACR Training Symposium, Jim Fultz walks through his HVAC 101 class to help techs get through any gas furnace call. Jim's core message is to start with your senses, not your meter. Look, listen, smell, and ask the homeowner what they experienced before touching a tool, then use instruments to confirm what your observations suggest.

An 80% furnace has a short list of components and a clear sequence of operations: call for heat, limit and pressure switch checks, inducer start, igniter warm-up, gas valve opening, flame proving, and the timed blower. When a furnace stops partway through that sequence, the stopping point tells you where to look. Jim also encourages techs to cycle a repaired furnace two or three times so they memorize what normal looks like, the way a bank teller learns real currency to spot counterfeits.

From there, Jim goes component by component, mixing practical tests with field stories. Topics include hot surface igniters, PSC and constant torque blower motors, capacitors, flame sensing, gas valves, pressure switches, and thermostat wiring. Along the way, he shares lessons such as checking amp draw even after a capacitor swap, measuring DC as well as AC on modern blower signals, and never assuming a wire's color is consistent from end to end. He also explains why wiring works as pairs, which makes board replacement far easier.

Jim closes with a look at truck stock and time management, pointing out that every parts run costs a billable hour. He also covers some White-Rodgers resources, including the mobile cross-reference app, universal controls, and private-label thermostats.

Topics Covered

  • Developing a troubleshooting thought process: observe first, measure second
  • Using the board LED, thermostat batteries, and float switches as quick first checks
  • Recreating the homeowner's complaint and listening to what customers report
  • Sequence of operation for an 80% furnace, including typical timings (15-second pre-purge, 17-second warm-up for 120V igniters, 5-second flame proving)
  • High-voltage versus low-voltage circuits, and why almost every component is wired in pairs
  • Tracing circuits on wiring diagrams one circuit at a time
  • Voltage versus continuity versus amperage: when to use each
  • Tracking down blown low-voltage fuses, from DIY thermostat installs to rubbed wires
  • Hot surface igniters: silicon carbide versus silicon nitride, cracks, and handling
  • PSC blowers, capacitor tolerances, and checking amp draw after a replacement
  • Constant torque (ECM X13) motors and the shift to DC control signals
  • Flame rectification: how it works, microamp readings, and cleaning the flame rod without sandpaper
  • Grounding problems, including a furnace that quit after a panel upgrade
  • Gas valves: DC coils, why you can't ohm them, and checking inlet gas first
  • Pressure switch testing tips and thermostat wire continuity checks
  • Truck stock strategy, universal controls, and the cost of parts runs

The key takeaway from this session is to pay attention to where the actual sequence of operations differs from the expected sequence.

This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Copeland, Santa Fe Dehumidifiers, and TruTech Tools.

Resources

Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.

Follow this show on AudioBrevity and new episodes get summarized for you. Create a free account

Couldn't load the audio. A blocker may be stopping the show's tracking links. Open the file