Why Every HVAC Company Needs a Home Performance Contractor - Short #312
· Summarized
Key takeaways
- Upsizing equipment or changing blower settings cannot correct a missing return path, duct leakage, pressure imbalance, or moisture pathway, and may create additional noise, power, and humidity problems.
- A technician should define the complaint precisely, verify equipment and airflow performance, inspect ordinary defects, and use pressure and leakage testing to distinguish equipment faults from building and distribution problems.
- Testing before and after a repair is more reliable than relying only on Manual J or Manual D modeling, because modeled leakage and load assumptions may not match the actual house.
- Cold rooms, sweating ducts, and clammy conditions require attention to dew point, runtime, moisture sources, and air/vapor pathways—not just the outdoor unit or duct size.
- HVAC companies that do not want to specialize in home performance should build reciprocal relationships with local building-science contractors who can test, diagnose, recommend, and generate referrals.
Summary
Why a bigger HVAC system is often an expensive guess
The host opens with a familiar complaint: a back bedroom is hot and the ducts are sweating, so another contractor recommends adding a ton of cooling. He argues that equipment capacity or fan-setting changes may miss problems involving ducts, the enclosure, moisture, pressure, roof leaks, or several interacting causes. Mike Cianfrocco’s symposium class makes the case for moving beyond ordinary HVAC diagnostics—not by requiring every technician to become a building-science expert, but by ensuring the company can access those testing skills when a problem house needs more than a replacement box.
Start with the complaint, then verify what the system delivers
The host says investigation should begin with specifics: which room, what time of day, whether doors are open or closed, and whether the symptom is temperature, humidity, a draft, odor, wet surfaces, or biological growth. Technicians can measure refrigerant, temperatures, amperage, voltage, and total airflow with tools such as MeasureQuick or a TrueFlow grid, while also inspecting filters, coils, duct sizes, kinks, crushed flex, and excessively long runs. But correct refrigerant readings or expected total airflow do not prove that every room receives adequate airflow.
A closed bedroom door can create the comfort problem
Using the bedroom example, the host explains that a supply register and hallway central return may work with the door open, but closing the door can pressurize the room because delivered air still needs a return path. A precision manometer can compare pressure with the blower off and on and with the door in each position. The repair might be a larger jump duct, an added transfer path, or a greater door undercut. More tonnage does not create the missing return path and may increase noise, power use, and blower stress.
Duct leakage can pull attic moisture into the house
Supply ducts leaking into a vented attic remove air from the house without returning it, encouraging attic-connected air to enter through gaps, cracks, can lights, and duct boots; in humid climates, that air carries moisture. A return leak can instead draw hot, humid, or contaminated attic air directly into the return stream, creating additional pressure and leakage effects. The host recommends testing in, repairing the leakage path, and testing out. Mike’s own house and a comparison model also demonstrated that leakage assumptions can change load calculations and equipment choices, though modeling is not a substitute for measured results.
Humidity and sweating ducts require system-level diagnosis
The host warns that a room can be cold yet clammy because sensible cooling and moisture removal are different tasks. Oversized equipment may cycle off quickly or fail to keep the coil cold long enough, sometimes removing less moisture than the old system. Technicians must examine runtime, indoor conditions, moisture sources, outdoor pathways, equipment operation, and even power bills rather than automatically downsizing. For sweating ducts, condensation means the surface is below the surrounding air’s dew point; solutions include warming the surface, lowering the surrounding dew point, repairing air/vapor control, encapsulating and dehumidifying a humid attic, or moving ducts into conditioned space.
Partner with a building-science specialist instead of doing everything yourself
The host explicitly says it is acceptable for an HVAC company to focus on repairs, replacements, and quality installations rather than becoming deeply specialized in every building-science test. Such a company should still understand airflow and duct design, but can refer difficult whole-home problems to a local building-science contractor who performs testing, writes recommendations, and works with the customer. The HVAC company can then complete the specified upgrades. The relationship can benefit both businesses: the specialist gains a capable installation partner, while the HVAC contractor may receive qualified leads.
Sponsors
- Carrier · Carrier’s GreenSpeed Extreme super-high-efficiency heat pumps are now available.
- Fieldpiece · The host directs listeners to Fieldpiece’s website.
- TruTech Tools · TruTech Tools carries more than 90 brands, ships to all 50 states and U.S. territories, provides free worksheets and resources, and offers technical support from tradespeople with field experience. The host specifically mentions Eric Kaiser and Bill Spohn, the company’s support for HVACR training, and the GETSCHOOLED discount code.
- Filtrete · Filtrete rates filters with both MERV and NPR, its Microparticle Performance Rating, which measures capture of tiny particles such as smoke and bacteria. The host says its pleated filters maintain similar airflow across MERV 8, 11, and 13, and cites California Energy Commission data ranking the 1900 NPR MERV 13 filter highest for airflow among available residential one-inch MERV 13 filters.
Show notes
In this short podcast episode, Bryan explains why every HVAC company needs a home performance contractor (or at least access to the skills provided by home performance contractors). Many people try to solve comfort issues by upsizing the equipment or changing fan settings, but there could be several building- or duct-related issues at play.
We start with complaints we can investigate, including discomfort in certain rooms or the presence of moisture or growth. Then, we can establish what the HVAC system is delivering with temperature, pressure, and electrical readings. Our senses can tell us if something might be wrong with the filter or the duct system. We can also use tools like the TrueFlow grid to measure airflow, but those don't necessarily tell us how air moves throughout a home, such as if there is an inadequate return path or if there are pressure imbalances between rooms. We can investigate those pressure imbalances with precision manometers, correct the complaint by adding or improving a return path, and test out after a solution has been implemented.
Supply ducts often leak into vented attics, which can cause attic air to enter the home and bring moisture with it. Return leaks can draw moist air directly into the return airstream, too. Again, we can test in, make a repair, and test out to improve those comfort and air quality problems.
Upsizing equipment as a response to comfort complaints can bring other issues. Rooms may be cold but clammy since short runtimes don't allow the coil to get cold enough for long enough to remove humidity effectively. Ultimately, we have to understand the entire system and the surrounding conditions (including dew point) when considering comfort solutions.
If your company does not have the means to do home performance testing, you and your customers may benefit from forming good relationships with contractors who offer home performance testing and solutions. Those contractors can also bring your business some leads in return.
This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Fieldpiece, TruTech Tools, and Filtrete.
Resources
- Mike Cianfrocco's Bry-X session (accessible with a virtual symposium ticket)
- An IAQ & Dehum Case Study w/ Genry and Nikki (podcast)
- Solving Comfort and IAQ Issues in a Vintage Home: A Case Study (tech tip)
- HVAC School calculators
- Submit a podcast question
- Learn about the GRIT Foundation
Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Follow this show on AudioBrevity and new episodes get summarized for you. Create a free account