HVAC School - For Techs, By Techs

The Fuse Only Blows When You Leave - Short #307

· Summarized

Share this episode
Anyone with this link can open it.
Share Link
Start at 0:00

Key takeaways

  • Always ask the customer what the system was doing right before the fuse blew, as this can offer valuable clues.
  • Inspect wiring for damage at common pinch points, outdoor exposure, or areas prone to wear and tear.
  • Use isolation diagnosis by labeling and disconnecting wires, then testing circuits individually to locate faults.
  • Never use a larger fuse to replace a blown fuse; it can mask underlying issues and cause further damage.
  • Environmental factors like moisture, vibration, and temperature changes can cause intermittent shorts that blow fuses under specific conditions.
  • Measure the current draw in various circuits during operation to identify overstressed or stuck components.
  • After fixing a fault, investigate what caused it—such as physical damage or environmental exposure—and repair those conditions.
  • Always follow manufacturer procedures and safety precautions when diagnosing control circuits, and verify repairs under all operating modes.

Summary

Introduction to the Blown Fuse Issue

The episode begins with the host, Brian, introducing the topic of a common but frustrating HVAC problem: a fuse that blows only when the technician leaves. He explains that this often happens after a repair, where the fuse blows again shortly after, usually when the system is operational or switching modes. The problem likely involves a short circuit or an abnormal current that only manifests under specific conditions, such as mode changes, moisture, vibration, or other environmental factors. Brian emphasizes the importance of understanding what the system was doing just before the fuse blew, as this can help narrow down the cause. The episode is aimed at technicians trying to troubleshoot these intermittent issues effectively.

Possible Causes and Diagnosis Strategies

Brian discusses various potential causes for the fuse blowing after leaving, such as wiring issues, ground faults, or shorts that occur only under certain conditions like rain, mode changes, or vibrations. He highlights the importance of asking the customer what the system was doing immediately prior to failure, even if their recollections are vague. The episode stresses the importance of inspecting wiring for damage or deterioration, especially at common pinch points or in outdoor environments. He advises using isolation diagnosis techniques, including labeling wires, taking photos before disconnecting, and testing circuits one at a time. Proper fuse protection and following manufacturer test procedures are emphasized over random jumping of calls or replacing larger fuses. The host also discusses the nuances of testing coils and controls, warning that continuity testing alone may not reveal intermittent shorts or faults.

Techniques for Troubleshooting and Preventing Recurrence

Brian advocates for a methodical approach: isolating circuits, testing individual conductors, and observing their behavior when energized. He recommends using modern thermostats with service modes to energize individual circuits and checking for high current draw or sticking relays and contactors. The episode warns about the influence of environmental factors like moisture, vibration, and temperature changes on intermittent faults, such as shorts caused by water in chases or corrosion. Furthermore, he notes that inductive loads like contactor coils can draw excessive current if they fail to fully engage or become stuck. Measuring current during operation can help identify overloaded or stuck components. Once a fault is identified and repaired, he advises investigating what caused it—be it physical damage, exposure to elements, or component failure—and fixing those issues to prevent future occurrences.

Additional Tips and Precautions for Service Technicians

Throughout the episode, Brian emphasizes safety and accuracy: confirming power is off before disconnecting wires, using proper fuse ratings, and following manufacturer test procedures. He notes that larger fuses are not a troubleshooting tool and warns against using them to mask underlying problems. The importance of inspecting for physical damage, such as pinched or corroded wires, is reiterated. He also discusses how inductive loads like contactor coils behave differently under power, noting that measuring resistance alone doesn't account for inductive reactance, which influences current draw during energization. The episode concludes with a reminder that after repairs, technicians should verify the fix under all operating modes and conditions, checking for signs of recurring issues like loose connections or environmental damage.

Final Advice and Summary

Wrapping up, Brian summarizes key points: understanding the system's behavior just before failure helps pinpoint causes; inspecting wires thoroughly and isolating circuits can reveal faults; environmental factors often contribute to intermittent shorts; and measuring current during operation is essential for diagnosing stuck components or overloads. He underscores the importance of fixing both the symptom (blown fuse) and the cause to prevent repeated failures. The episode aims to equip technicians with practical, real-world troubleshooting techniques based on experience and safety best practices.

Sponsors

  • Refrigeration Technologies · Viper wipes, the all-purpose wipe that is really amazing what it can cut through, from plastic to oil, grease, tar, grime, and it's nice on the hands.
  • Carrier · Carrier has their new green speed, extreme, super high efficiency heat pumps out on the market now.
  • Fieldpeace and TrueTechTools · TrueTechTools offers over 90 brands, has a support team of tradespeople, and supports industry training, including the HVAC training symposium. Use code GetSchooled for discounts.
  • Filtrate · Filtrate rates its filters' effectiveness with Merv and NPR ratings, and their filters can capture microscopic particles like smoke and bacteria, with the highest airflow among residential filters.

Show notes

In this short podcast episode, Bryan talks about the fuse that only blows when you leave. The service call usually goes like this: you replace a blown fuse, the system runs fine, you leave, and then the fuse blows again. There could be several causes of a blown fuse.

First, ask what was happening right before the system stopped, such as if the unit was starting up, if it was raining outside, or if the operating mode changed. The customer may not know the specifics, but they may be able to offer a clue. If the control fuse blows during a specific call, we may be able to locate a short in one of the circuits involved. We may also be able to find out a bit by inspecting places where wire often gets damaged, such as common points where conductors pinch or rub.  

Isolation diagnosis can help us isolate the specific circuit or component with a problem. First, look at the wiring diagram, label conductors, and take pictures of the original setup before disconnecting anything. Keep the correct fuse protection instead of using a larger fuse, leave all safety controls in the circuit, and use the manufacturer's test procedure if it's available. Then, isolate different loads and conductors so they can be energized individually; some modern thermostats make this easy. Also note that continuity testing alone isn't always reliable for locating problematic paths.

Sometimes, motion (from motors), temperature, and moisture can also contribute to intermittent issues. Additionally, some inductive loads, like contactor coils, experience unique intermittent issues that cause the components to draw high current; inductive reactance matters. Measuring current on the different circuits as you energize them can also point you toward circuits that have higher current than expected.

Once you've found and repaired something, go back to the condition that made it fail. Make sure you fix the underlying problem, such as exposure to excess heat, vibration, or moisture.

This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Fieldpiece, TruTech Tools, and Filtrete.

Resources

Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.

Follow this show on AudioBrevity and new episodes get summarized for you. Create a free account

Couldn't load the audio. A blocker may be stopping the show's tracking links. Open the file